Chittenango Creek Red Flag Monitoring Event on June 27, 2024, under Base Flow conditions
Chittenango Creek Monitoring Event Graph
This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.
Event Results
Scroll down to view the event results for each monitoring location.
Location | Analyte | Value | Remarks | Location |
---|---|---|---|---|
Chittenango @ Retirement Home | Hardness, Total | 326.0 mg CaCO3/L | not certified | Field |
Hydrogen Ion (pH) | 8.0 Unitless (negative logarithm of H ion concentration) | not certified | Field | |
Specific Conductance | 782.0 uS/cm | not certified | Field | |
Dissolved Oxygen | 8.5 mg/L | not certified | Field | |
Temperature | 18.1 C | not certified | Field | |
Chittenango @ Sewage Treatment Plant | Temperature | 19.3 C | not certified | Field |
Hydrogen Ion (pH) | 8.0 Unitless (negative logarithm of H ion concentration) | not certified | Field | |
Specific Conductance | 475.0 uS/cm | not certified | Field | |
Dissolved Oxygen | 7.2 mg/L | not certified | Field | |
Hardness, Total | 148.0 mg CaCO3/L | not certified | Field | |
Chittenango @ DEC Parking Lot | Hardness, Total | 160.0 mg CaCO3/L | not certified | Field |
Specific Conductance | 445.0 uS/cm | not certified | Field | |
Hydrogen Ion (pH) | 8.5 Unitless (negative logarithm of H ion concentration) | not certified | Field | |
Temperature | 19.1 C | not certified | Field | |
Dissolved Oxygen | 8.2 mg/L | not certified | Field |