Fall Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Lafayette Road Soluble Reactive Phosphorus (as P) 6.11 ug/L Exceeded 15 min. holding time for filtration Lab
Chloride 21.6 mg/L Lab
Turbidity 2.1 NTU Field blank failed, results may be biased high Lab
Total Phosphorus (as P) 12.8 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.85 mg/L Lab
Solids, Total Suspended 1.25 mg/L Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
E. Coli 20.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
Specific Conductance 326.0 uS/cm Field blank failed, results may be biased high Lab
Davis Road Bridge Soluble Reactive Phosphorus (as P) 14.9 ug/L Exceeded 15 min. holding time for filtration Lab
Chloride 23.7 mg/L Lab
Turbidity 2.6 NTU Field blank failed, results may be biased high Lab
Total Phosphorus (as P) 20.6 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.23 mg/L Lab
Specific Conductance 359.0 uS/cm Field blank failed, results may be biased high Lab
Solids, Total Suspended 1.75 mg/L Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
E. Coli 220.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
Fall Creek Freeville E. Coli 160.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
Chloride 32.8 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.38 mg/L Estimate Lab
Total Phosphorus (as P) 19.3 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.1 mg/L Lab
Temperature 15.0 C Field
Soluble Reactive Phosphorus (as P) 15.6 ug/L Exceeded 15 min. holding time for filtration Lab
Specific Conductance 433.0 uS/cm Field blank failed, results may be biased high Lab
Solids, Total Suspended 5.75 mg/L Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
Turbidity 7.9 NTU Field blank failed, results may be biased high Lab
Freese Road Bridge Turbidity 2.3 NTU Field blank failed, results may be biased high Lab
Specific Conductance 451.0 uS/cm Field blank failed, results may be biased high Lab
Temperature 15.0 C Field
Soluble Reactive Phosphorus (as P) 5.95 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 25.6 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.93 mg/L Lab
Chloride 41.1 mg/L Lab
Solids, Total Suspended 0.63 mg/L non-detect; Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
E. Coli 20.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
Cayuga Street Bridge Chloride 47.7 mg/L Lab
Total Phosphorus (as P) 15.6 ug/L Lab
Kjeldahl Nitrogen, Total (as N) 0.43 mg/L Estimate Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.89 mg/L Lab
E. Coli 60.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
Turbidity 12.0 NTU Field blank failed, results may be biased high Lab
Soluble Reactive Phosphorus (as P) 4.08 ug/L Exceeded 15 min. holding time for filtration Lab
Temperature 14.5 C Field
Solids, Total Suspended 12.0 mg/L Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Field
Specific Conductance 450.0 uS/cm Field blank failed, results may be biased high Lab
Fall Creek Forest Home Turbidity 5.6 NTU Field blank failed, results may be biased high Lab
Chloride 40.7 mg/L Lab
Total Phosphorus (as P) 16.2 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.85 mg/L Lab
Temperature 16.0 C Field
Soluble Reactive Phosphorus (as P) 17.5 ug/L Exceeded 15 min. holding time for filtration Lab
Specific Conductance 447.0 uS/cm Field blank failed, results may be biased high Lab
Solids, Total Suspended 3.0 mg/L Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
E. Coli 20.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
McLean Rd. Soluble Reactive Phosphorus (as P) 16.1 ug/L Exceeded 15 min. holding time for filtration Lab
Chloride 30.3 mg/L Lab
Turbidity 3.0 NTU Field blank failed, results may be biased high Lab
Total Phosphorus (as P) 15.9 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.36 mg/L Lab
Temperature 11.5 C Field
Solids, Total Suspended 2.75 mg/L Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
E. Coli 80.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
Specific Conductance 416.0 uS/cm Field blank failed, results may be biased high Lab
Fall Creek Fire Department Turbidity 1.8 NTU Field blank failed, results may be biased high Lab
Chloride 24.8 mg/L Lab
Temperature 11.5 C Field
Total Phosphorus (as P) 12.8 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.36 mg/L Lab
Soluble Reactive Phosphorus (as P) 7.36 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 4.0 mg/L Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
Specific Conductance 384.0 uS/cm Field blank failed, results may be biased high Lab
E. Coli 160.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
Como Lake Outlet Soluble Reactive Phosphorus (as P) 12.0 ug/L Exceeded 15 min. holding time for filtration Lab
Turbidity 2.3 NTU Field blank failed, results may be biased high Lab
Total Phosphorus (as P) 29.8 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.26 mg/L Lab
Chloride 17.6 mg/L Lab
Specific Conductance 276.0 uS/cm Field blank failed, results may be biased high Lab
Solids, Total Suspended 0.63 mg/L non-detect; Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
E. Coli 80.0 Colonies/100 ml Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab
Champlin Road Culvert Soluble Reactive Phosphorus (as P) 237.0 ug/L Exceeded 15 min. holding time for filtration Lab
Chloride 23.8 mg/L Lab
Turbidity 9.7 NTU Field blank failed, results may be biased high Lab
Total Phosphorus (as P) 290.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 3.09 mg/L Lab
Solids, Total Suspended 15.3 mg/L Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small Lab
Specific Conductance 560.0 uS/cm Field blank failed, results may be biased high Lab
E. Coli 50.0 Colonies/100 ml non-detect; Field duplicate exceeds criteria based on RPD, but absolute concentration difference is relatively small considering the number of colonies cultured Lab