Virgil Creek Synoptic Monitoring Event on September 12, 2022, under Base Flow conditions
Virgil Creek Monitoring Event Graph
This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.
Event Results
Scroll down to view the event results for each monitoring location.
Location | Analyte | Value | Remarks | Location |
---|---|---|---|---|
Dryden Lake Outlet | Temperature | 17.0 C | Field | |
Turbidity | 40.0 NTU | Lab | ||
Solids, Total Suspended | 29.7 mg/L | Lab | ||
E. Coli | 130.0 Colonies/100 ml | Lab | ||
Total Phosphorus (as P) | 93.0 ug/L | Lab | ||
Specific Conductance | 284.0 uS/cm | Lab | ||
Chloride | 22.7 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 4.86 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Nitrate-+Nitrite-Nitrogen (as N) | 0.005 mg/L | non-detect | Lab | |
Virgil Creek Road | Specific Conductance | 451.0 uS/cm | Lab | |
Turbidity | 9.5 NTU | Lab | ||
Chloride | 46.8 mg/L | Lab | ||
Solids, Total Suspended | 11.0 mg/L | Lab | ||
E. Coli | 160.0 Colonies/100 ml | Lab | ||
Temperature | 15.0 C | Field | ||
Total Phosphorus (as P) | 16.7 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.67 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 4.39 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Spring House Bridge | E. Coli | 210.0 Colonies/100 ml | Lab | |
Chloride | 42.3 mg/L | Lab | ||
Solids, Total Suspended | 9.67 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 3.77 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Nitrate-+Nitrite-Nitrogen (as N) | 0.53 mg/L | Lab | ||
Total Phosphorus (as P) | 36.0 ug/L | Lab | ||
Specific Conductance | 443.0 uS/cm | Lab | ||
Turbidity | 12.0 NTU | Lab | ||
Dryden Lake Inlet | Temperature | 8.0 C | Field | |
Chloride | 34.8 mg/L | Lab | ||
Turbidity | 4.5 NTU | Lab | ||
Soluble Reactive Phosphorus (as P) | 13.6 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Solids, Total Suspended | 8.4 mg/L | Lab | ||
E. Coli | 790.0 Colonies/100 ml | Lab | ||
Total Phosphorus (as P) | 22.8 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 5.29 mg/L | Lab | ||
Specific Conductance | 486.0 uS/cm | Lab | ||
Virgil Creek Freeville | Chloride | 49.2 mg/L | Lab | |
Turbidity | 18.0 NTU | Lab | ||
E. Coli | 340.0 Colonies/100 ml | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.26 mg/L | Lab | ||
Temperature | 19.0 C | Field | ||
Total Phosphorus (as P) | 45.3 ug/L | Lab | ||
Kjeldahl Nitrogen, Total (as N) | 0.59 mg/L | Lab | ||
Specific Conductance | 466.0 uS/cm | Lab | ||
Solids, Total Suspended | 17.7 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 14.7 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Dryden Lake Park | Turbidity | 50.0 NTU | Lab | |
Specific Conductance | 260.0 uS/cm | Lab | ||
Solids, Total Suspended | 34.2 mg/L | Lab | ||
Temperature | 17.0 C | Field | ||
Total Phosphorus (as P) | 106.0 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.02 mg/L | Lab | ||
Chloride | 19.1 mg/L | Lab | ||
E. Coli | 50.0 Colonies/100 ml | Lab | ||
Soluble Reactive Phosphorus (as P) | 12.5 ug/L | Exceeded 15 min. holding time for filtration | Lab |