Location Analyte Value Remarks Location
Cayuga Nature Center Creek at Center - Upstream Temperature 7.0 C Field
Specific Conductance 611.0 uS/cm Lab
Chloride 63.9 mg/L Lab
Turbidity 1.4 NTU Lab
Solids, Total Suspended 0.25 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 8.66 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 17.7 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.44 mg/L Lab
E. Coli 1400.0 Colonies/100 ml Lab
Cayuga Nature Center Creek at Comstock Temperature 7.0 C Field
Specific Conductance 613.0 uS/cm Lab
Chloride 60.7 mg/L Lab
Turbidity 1.5 NTU Lab
Solids, Total Suspended 0.25 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 9.89 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 18.5 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.47 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.17 mg/L non-detect Lab
E. Coli 1000.0 Colonies/100 ml Lab