Baldwin Creek Monitoring Event Graph

Use graph legend to de-select indicators in order to view indicators of interest. All event results are reported in the table below. Note that exceptionally low values may not register on the graph.

Event Results

Location Analyte Value Remarks Location
Goldsmith Creek @ Draht Hill Rd Temperature 18.5 C Field
Hydrogen Ion (pH) 7.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 309.0 uS/cm Field
Hardness, Total 66.0 mg CaCO3/L Field
Dissolved Oxygen 10.4 mg/L Field
Baldwin Creek @ County Rd 1 Temperature 20.0 C Field
Hydrogen Ion (pH) 7.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 234.0 uS/cm Field
Hardness, Total 42.0 mg CaCO3/L Field
Dissolved Oxygen 10.0 mg/L Field
Baldwin Creek @ Jenkins Rd Temperature 20.0 C Field
Hydrogen Ion (pH) 7.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 235.0 uS/cm Field
Hardness, Total 58.0 mg CaCO3/L Field
Dissolved Oxygen 9.0 mg/L Field