Upper Susquehanna Tributaries Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Wilkins Brook @ Cnty Rd 17 Temperature 9.0 C Field
Hydrogen Ion (pH) 7.5 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 88.0 uS/cm Field
Hardness, Total 23.0 mg CaCO3/L Field
Kelsey Brook @ Algerine St Temperature 9.0 C Field
Hydrogen Ion (pH) 7.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 86.0 uS/cm Field
Hardness, Total 25.0 mg CaCO3/L Field
Bumps Creek @ School Parking Lot Temperature 8.0 C Field
Hydrogen Ion (pH) 7.5 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 51.0 uS/cm Field
Hardness, Total 24.0 mg CaCO3/L Field
Cornell Creek @ Decker Rd Temperature 8.0 C Field
Hydrogen Ion (pH) 7.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 70.5 uS/cm Field
Hardness, Total 32.0 mg CaCO3/L Field
Wylie Brook @ Rt 7 & 235 Temperature 10.0 C Field
Hydrogen Ion (pH) 6.75 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 65.0 uS/cm Field
Hardness, Total 28.0 mg CaCO3/L Field