Notes:
Taughannock Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Taughannock Falls
(TGF)
Turbidity 6.22 NTU Lab
Total Phosphorus (as P) 17.3 ug/L Lab
Total Coliform 18500.0 Colonies/100 ml Lab
Temperature 8.0 C Field
Specific Conductance 388.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 8.93 ug/L Lab
Solids, Total Suspended 3.75 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 3.98 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.595 mg/L Lab
Hydrogen Ion (pH) 7.75 Unitless (negative logarithm of H ion concentration) Not a certifiable test Lab
Hardness, Total 165.0 mg CaCO3/L Lab
E. Coli 460.0 Colonies/100 ml Lab
Chloride 23.7 mg/L Lab
Alkalinity 111.0 mg CaCO3/L Lab