Partial Monitoring Event on September 28, 2011
for Cayuta Creek under Base Flow conditions
Notes:
Cayuta Creek Monitoring Event Graph
This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.
Event Results
Scroll down to view the event results for each monitoring location.
Location | Analyte | Value | Units | Remarks | Location |
---|---|---|---|---|---|
Upper Langford (CCH2) |
Temperature | 10.0 | C | Field | |
Hydrogen Ion (pH) | 6.5 | Unitless (negative logarithm of H ion concentration) | Not Certifiable | Field | |
Hardness, Total | 28.0 | mg CaCO3/L | Field | ||
Dissolved Oxygen | 6.0 | mg/L | Field | ||
Poysa Feeder (CCH1) |
Temperature | 11.0 | C | Field | |
Specific Conductance | 123.0 | uS/cm | Field | ||
Hydrogen Ion (pH) | 7.0 | Unitless (negative logarithm of H ion concentration) | Not Certifiable | Field | |
Hardness, Total | 44.0 | mg CaCO3/L | Field | ||
Dissolved Oxygen | 7.2 | mg/L | Field | ||
Upper McDuffy Creek (Mt. Elston) (CCH3) |
Temperature | 11.0 | C | Field | |
Hydrogen Ion (pH) | 6.5 | Unitless (negative logarithm of H ion concentration) | Not Certifiable | Field | |
Hardness, Total | 20.0 | mg CaCO3/L | Field | ||
Dissolved Oxygen | 6.7 | mg/L | Field | ||
McDuffy Creek @ 224 (UC4M) |
Temperature | 17.0 | C | Expanded QC criteria | Field |
Specific Conductance | 108.0 | uS/cm | Field | ||
Hydrogen Ion (pH) | 7.0 | Unitless (negative logarithm of H ion concentration) | Not Certifiable; Expanded QC criteria | Field | |
Hardness, Total | 46.0 | mg CaCO3/L | Field | ||
Dissolved Oxygen | 9.0 | mg/L | Field | ||
Jackson Creek @ 224 (UC3J) |
Temperature | 18.0 | C | Expanded QC criteria | Field |
Specific Conductance | 89.0 | uS/cm | Field | ||
Hydrogen Ion (pH) | 7.0 | Unitless (negative logarithm of H ion concentration) | Not Certifiable | Field | |
Hardness, Total | 39.0 | mg CaCO3/L | Field | ||
Dissolved Oxygen | 9.4 | mg/L | Field | ||
Cayuta Public Pull Out on 224 (UC2C) |
Temperature | 17.0 | C | Expanded QC criteria | Field |
Specific Conductance | 236.0 | uS/cm | Field | ||
Hydrogen Ion (pH) | 7.0 | Unitless (negative logarithm of H ion concentration) | Not Certifiable; Expanded QC criteria | Field | |
Hardness, Total | 96.0 | mg CaCO3/L | Field | ||
Dissolved Oxygen | 8.6 | mg/L | Field | ||
Pony Hollow Creek (UC5P) |
Temperature | 15.0 | C | Expanded QC criteria | Field |
Specific Conductance | 222.0 | uS/cm | Field | ||
Hydrogen Ion (pH) | 7.0 | Unitless (negative logarithm of H ion concentration) | Not Certifiable; Expanded QC criteria | Field | |
Hardness, Total | 98.0 | mg CaCO3/L | Field | ||
Dissolved Oxygen | 8.6 | mg/L | Field | ||
Cayuta Creek in Alpine (UC1A) |
Temperature | 20.0 | C | Expanded QC criteria | Field |
Specific Conductance | 164.0 | uS/cm | Field | ||
Hydrogen Ion (pH) | 7.0 | Unitless (negative logarithm of H ion concentration) | Not Certifiable; Expanded QC criteria | Field | |
Hardness, Total | 84.0 | mg CaCO3/L | Field | ||
Dissolved Oxygen | 8.2 | mg/L | Field |