Cayuta Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Pony Hollow Creek Specific Conductance 118.0 uS/cm Field
Langford Creek @ Railroad Dissolved Oxygen 9.4 mg/L Field
Temperature 11.0 C Field
Specific Conductance 66.0 uS/cm Expanded QC criteria Field
Hardness, Total 20.0 mg CaCO3/L Field
Cayuta Creek @ Stoschecks Temperature 10.0 C Field
Specific Conductance 118.0 uS/cm Field
Hardness, Total 44.0 mg CaCO3/L Field
Dissolved Oxygen 10.2 mg/L Field
Darling Creek Temperature 10.0 C Field
Specific Conductance 28.0 uS/cm Field
Hardness, Total 44.0 mg CaCO3/L Field
Dissolved Oxygen 10.2 mg/L Field
Cayuta Creek @ Kelley Rd Temperature 11.0 C Field
Specific Conductance 118.0 uS/cm Field
Hardness, Total 48.0 mg CaCO3/L Field
Dissolved Oxygen 9.6 mg/L Field
Cayuta Creek @ Wyncoop Creek Temperature 10.0 C Field
Hardness, Total 44.0 mg CaCO3/L Field
Dissolved Oxygen 9.0 mg/L Field
Dean Creek Temperature 11.5 C Field
Hydrogen Ion (pH) 7.64 Unitless (negative logarithm of H ion concentration) Not certifiable Field
Specific Conductance 74.5 uS/cm Field
Dissolved Oxygen 9.8 mg/L Field