Notes: Event Time = Average Time of sampling (Eastern Time)
Canoga Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Canoga Creek South Branch
(CASB)
Turbidity 4.4 NTU Lab
Total Phosphorus (as P) 33.6 ug/L Lab
Temperature 12.0 C Field
Specific Conductance 828.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 16.0 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 3.14 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.11 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.1 mg/L non-detect Lab
Hydrogen Ion (pH) 8.0 Unitless (negative logarithm of H ion concentration) Not Certifiable Lab
Hardness, Total 405.0 mg CaCO3/L Lab
E. Coli 660.0 Colonies/100 ml Lab
Chloride 41.1 mg/L Lab
Alkalinity 224.0 mg CaCO3/L Sample collected with head space Lab
Canoga Creek North Branch
(CANB)
Turbidity 3.0 NTU Lab
Total Phosphorus (as P) 57.1 ug/L Lab
Temperature 13.0 C Field
Specific Conductance 1792.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 32.5 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 1.71 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.07 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.1 mg/L non-detect Lab
Hydrogen Ion (pH) 7.75 Unitless (negative logarithm of H ion concentration) Not Certifiable Lab
Hardness, Total 945.0 mg CaCO3/L Lab
E. Coli 80.0 Colonies/100 ml Lab
Chloride 48.0 mg/L Lab
Alkalinity 269.0 mg CaCO3/L Sample collected with head space Lab