Notes: Field blank failed for conductivity; These data are not reported here.
Burroughs Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Williamson Creek
(CAWM)
Turbidity 9.2 NTU Lab
Total Phosphorus (as P) 156.0 ug/L Lab
Temperature 20.0 C Field
Soluble Reactive Phosphorus (as P) 111.0 ug/L Exceeded 15 min. holding time for filtration; Pre-dilution concentrations for the primary sample and the field duplicate were <17 ug P/L with an abosulte difference of 5.5 ug P/L. A difference of +/-5.7 ug P/L is acceptable for duplicate results <17.0 ug P/L. Lab
Solids, Total Suspended 2.86 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 19.1 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.17 mg/L non-detect; Result may be biased low when Nitrate+Nitrite Nitrogen (as N) > 4 mg/L Lab
E. Coli 1950.0 Colonies/100 ml High RPD between primary sample and field duplicate for E. coli. Absolute difference for raw colony count on each culture plate was small (<10 raw colonies). Lab
Chloride 60.4 mg/L Lab
Burroughs Creek
(CABU)
Turbidity 7.1 NTU Lab
Total Phosphorus (as P) 73.2 ug/L Lab
Temperature 22.0 C Field
Soluble Reactive Phosphorus (as P) 21.6 ug/L Exceeded 15 min. holding time for filtration; Pre-dilution concentrations for the primary sample and the field duplicate were <17 ug P/L with an abosulte difference of 5.5 ug P/L. A difference of +/-5.7 ug P/L is acceptable for duplicate results <17.0 ug P/L. Lab
Solids, Total Suspended 2.57 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 5.49 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.34 mg/L Estimate; Result may be biased low when Nitrate+Nitrite Nitrogen (as N) > 4 mg/L Lab
E. Coli 450.0 Colonies/100 ml High RPD between primary sample and field duplicate for E. coli. Absolute difference for raw colony count on each culture plate was small (<10 raw colonies). Lab
Chloride 20.3 mg/L Lab
Burroughs Creek @ Seybolt Road
(CABUS)
Turbidity 5.7 NTU Lab
Total Phosphorus (as P) 108.0 ug/L Lab
Temperature 21.0 C Field
Soluble Reactive Phosphorus (as P) 62.4 ug/L Exceeded 15 min. holding time for filtration;Pre-dilution concentrations for the primary sample and the field duplicate were <17 ug P/L with an abosulte difference of 5.5 ug P/L. A difference of +/-5.7 ug P/L is acceptable for duplicate results <17.0 ug P/L. Lab
Solids, Total Suspended 0.72 mg/L non-detect Lab
Nitrate-+Nitrite-Nitrogen (as N) 4.53 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.75 mg/L Result may be biased low when Nitrate+Nitrite Nitrogen (as N) > 4 mg/L Lab
E. Coli 400.0 Colonies/100 ml High RPD between primary sample and field duplicate for E. coli. Absolute difference for raw colony count on each culture plate was small (<10 raw colonies). Lab
Chloride 39.6 mg/L Lab