Notes: Event Time = Time of sampling (Eastern Time) at stream mouth (Big Stream Mouth@Glenora Pt.)
Big Stream Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Dundee WWTP Discharge
(BSWP)
Total Phosphorus (as P) 2052.0 ug/L Lab
Temperature 16.0 C Field
Specific Conductance 1156.0 uS/cm Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 1921.0 ug/L Lab
Solids, Total Suspended 4.2 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.51 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 2.15 mg/L Lab
E. Coli 14067.0 Colonies/100 ml Lab
Upstream Dundee Wastewater Plant
(BSUW)
Total Phosphorus (as P) 42.6 ug/L Lab
Temperature 15.0 C Field
Specific Conductance 475.0 uS/cm Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 12.5 ug/L Lab
Solids, Total Suspended 23.4 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.3 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.57 mg/L Lab
E. Coli 160.0 Colonies/100 ml Lab
Big Stream Mouth @ Glenora Point
(BSGP)
Total Phosphorus (as P) 89.9 ug/L Lab
Temperature 15.0 C Field
Specific Conductance 611.0 uS/cm Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 72.4 ug/L Lab
Solids, Total Suspended 0.5 mg/L non-detect Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.3 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.44 mg/L Lab
E. Coli 100.0 Colonies/100 ml Lab
Big Stream @ Dundee-Glenora Rd
(BSDG)
Total Phosphorus (as P) 148.0 ug/L Lab
Temperature 16.0 C Field
Specific Conductance 655.0 uS/cm Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 111.0 ug/L Lab
Solids, Total Suspended 3.6 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.39 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.64 mg/L Lab
E. Coli 600.0 Colonies/100 ml Lab