Big Stream Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Dundee WWTP Discharge Specific Conductance 1156.0 uS/cm Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 1921.0 ug/L Lab
Kjeldahl Nitrogen, Total (as N) 2.15 mg/L Lab
Total Phosphorus (as P) 2052.0 ug/L Lab
Solids, Total Suspended 4.2 mg/L Lab
E. Coli 14067.0 Colonies/100 ml Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.51 mg/L Lab
Temperature 16.0 C Field
Big Stream Mouth @ Glenora Point E. Coli 100.0 Colonies/100 ml Lab
Temperature 15.0 C Field
Kjeldahl Nitrogen, Total (as N) 0.44 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.3 mg/L Lab
Total Phosphorus (as P) 89.9 ug/L Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 72.4 ug/L Lab
Specific Conductance 611.0 uS/cm Lab
Solids, Total Suspended 0.5 mg/L non-detect Lab
Big Stream @ Dundee-Glenora Rd E. Coli 600.0 Colonies/100 ml Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 111.0 ug/L Lab
Kjeldahl Nitrogen, Total (as N) 0.64 mg/L Lab
Temperature 16.0 C Field
Solids, Total Suspended 3.6 mg/L Lab
Total Phosphorus (as P) 148.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.39 mg/L Lab
Specific Conductance 655.0 uS/cm Lab
Upstream Dundee Wastewater Plant Temperature 15.0 C Field
Solids, Total Suspended 23.4 mg/L Lab
E. Coli 160.0 Colonies/100 ml Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 12.5 ug/L Lab
Kjeldahl Nitrogen, Total (as N) 0.57 mg/L Lab
Total Phosphorus (as P) 42.6 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.3 mg/L Lab
Specific Conductance 475.0 uS/cm Lab