Notes: Event Time = Time of sampling (Eastern Time) at stream mouth (Plain St.) Irish Settlement Road (IRISH) - "Extensive Beaver Dam"
Six Mile Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Yellow Barn Road
(Yellow Barn)
Turbidity 1.6 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 7.59 ug/L Lab
Temperature 4.0 C Field
Specific Conductance 107.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 4.09 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 0.63 mg/L non-detect; Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.04 mg/L Lab
E. Coli 5.0 Colonies/100 ml non-detect Lab
Chloride 16.8 mg/L Lab
Banks Road
(Banks)
Turbidity 5.7 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 6.34 ug/L Lab
Temperature 10.0 C Field
Specific Conductance 344.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 2.83 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 3.25 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.03 mg/L Lab
E. Coli 30.0 Colonies/100 ml Lab
Chloride 35.8 mg/L Lab
Irish Settlement Rd
(Irish)
Turbidity 5.4 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 18.2 ug/L Lab
Temperature 9.0 C Field
Specific Conductance 224.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 4.23 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 4.25 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.08 mg/L Lab
E. Coli 120.0 Colonies/100 ml Lab
Chloride 30.2 mg/L Lab
Six Hundred Rd
(600 Rd)
Turbidity 1.0 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 5.09 ug/L Lab
Temperature 9.0 C Field
Specific Conductance 260.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 3.61 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 0.63 mg/L non-detect; Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.06 mg/L Lab
E. Coli 10.0 Colonies/100 ml Lab
Chloride 26.0 mg/L Lab
Boiceville
(Boiceville)
Turbidity 0.7 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 4.47 ug/L Lab
Specific Conductance 328.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 5.48 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 0.63 mg/L non-detect; Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.1 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.13 mg/L non-detect Lab
E. Coli 10.0 Colonies/100 ml Lab
Chloride 31.2 mg/L Lab
Beaver Creek
(Beaver)
Turbidity 5.8 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 16.5 ug/L Lab
Specific Conductance 268.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 6.27 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 3.0 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.05 mg/L Lab
E. Coli 10.0 Colonies/100 ml Lab
Chloride 22.2 mg/L Lab
Brooktondale
(B\dale)
Turbidity 1.2 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 5.41 ug/L Lab
Specific Conductance 342.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 2.22 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 0.63 mg/L non-detect; Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.09 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.13 mg/L non-detect Lab
E. Coli 40.0 Colonies/100 ml Lab
Chloride 36.0 mg/L Lab
Spur Creek
()
Turbidity 2.2 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 13.5 ug/L Lab
Temperature 6.0 C Field
Specific Conductance 33.9 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 7.05 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 5.25 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.09 mg/L Lab
E. Coli 5.0 Colonies/100 ml non-detect Lab
Chloride 1.3 mg/L non-detect Lab
Gasline
(Gasline)
Turbidity 8.7 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 6.03 ug/L Lab
Temperature 7.0 C Field
Specific Conductance 349.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 5.8 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 3.0 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.005 mg/L non-detect Lab
E. Coli 5.0 Colonies/100 ml non-detect Lab
Chloride 34.7 mg/L Lab
Midline Rd
(Midline)
Turbidity 2.8 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 13.1 ug/L Lab
Temperature 8.0 C Field
Specific Conductance 303.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 3.92 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 1.75 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.12 mg/L Lab
E. Coli 10.0 Colonies/100 ml Lab
Chloride 44.6 mg/L Lab
Barrile Site
(Barille)
Turbidity 1.4 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 4.63 ug/L Lab
Temperature 9.0 C Field
Specific Conductance 278.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 4.08 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 0.63 mg/L non-detect; Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.16 mg/L Lab
E. Coli 20.0 Colonies/100 ml Lab
Chloride 26.4 mg/L Lab
Horse Farm
(Horse)
Turbidity 2.6 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 8.06 ug/L Lab
Specific Conductance 256.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 3.16 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 0.63 mg/L non-detect; Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.005 mg/L non-detect Lab
E. Coli 10.0 Colonies/100 ml Lab
Chloride 27.0 mg/L Lab
German Cross Road
(German)
Turbidity 9.6 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 7.44 ug/L Lab
Temperature 9.5 C Field
Specific Conductance 344.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 4.86 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 4.0 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.02 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.13 mg/L non-detect Lab
E. Coli 20.0 Colonies/100 ml Lab
Chloride 36.0 mg/L Lab
Wildflower Preserve
(Wildflower)
Turbidity 9.8 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 16.5 ug/L Lab
Temperature 14.0 C Field
Specific Conductance 336.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 2.98 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 13.5 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.04 mg/L Lab
E. Coli 20.0 Colonies/100 ml Lab
Chloride 35.4 mg/L Lab
Plain Street
(Plain)
Turbidity 6.4 NTU Field blank failed for turbidity (FB=0.55 NTU). Turbidity results may be biased high. Criterion is <0.1 NTU. Lab
Total Phosphorus (as P) 11.7 ug/L Lab
Temperature 10.0 C Field
Specific Conductance 353.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Soluble Reactive Phosphorus (as P) 2.67 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 3.0 mg/L Field duplicate failed marginally for total suspended solids, 24% RPD allowed for duplicates. TSS results may not be representative of sampling location. Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.04 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.13 mg/L non-detect Lab
E. Coli 40.0 Colonies/100 ml Lab
Chloride 40.3 mg/L Lab
Brooktondale GW
()
Specific Conductance 396.0 uS/cm Field blank failed marginally for conductivity (FB=1.3 uS/cm). Conductivity results may be biased high. Criterion is <1.0 uS/cm. Lab
Dissolved Oxygen 10.2 mg/L Fixed in field by volunteers; not certifiable Lab