Notes:
Cayuga Inlet Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Cascadilla Creek Mouth
(CCM)
Turbidity 14.0 NTU Lab
Total Phosphorus (as P) 44.0 ug/L Lab
Specific Conductance 8.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 14.1 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 5.75 mg/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.22 mg/L Lab
Hydrogen Ion (pH) 8.0 Unitless (negative logarithm of H ion concentration) Not certifiable Lab
Hardness, Total 123.0 mg CaCO3/L Lab
E. Coli 150.0 Colonies/100 ml Lab
Chloride 37.3 mg/L Lab
Alkalinity 115.0 mg CaCO3/L Sample collected with head space Lab