Johnsons Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Johnsons Creek Headwaters Alkalinity 275.0 mg CaCO3/L Sample collected with head space Lab
Temperature 18.0 C Field
Hydrogen Ion (pH) 8.04 Unitless (negative logarithm of H ion concentration) Not Certifiable Lab
Specific Conductance 1272.0 uS/cm Lab
Chloride 199.0 mg/L Lab
Turbidity 26.0 NTU Lab
Solids, Total Suspended 16.5 mg/L Lab
Soluble Reactive Phosphorus (as P) 575.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 970.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.77 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 6.6 mg/L Lab
E. Coli 34800.0 Colonies/100 ml Lab
Johnsons Creek - Dump Temperature 18.0 C Field
Specific Conductance 1120.0 uS/cm Lab
Chloride 191.0 mg/L Lab
Turbidity 13.0 NTU Lab
Soluble Reactive Phosphorus (as P) 218.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 279.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.39 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 1.35 mg/L Lab
E. Coli 6000.0 Colonies/100 ml Lab