Stewart Park Monitoring Event Graph

Use graph legend to de-select indicators in order to view indicators of interest. All event results are reported in the table below. Note that exceptionally low values may not register on the graph.

Event Results

Location Analyte Value Remarks Location
Renwick Brook South Temperature 15.0 C Field
Specific Conductance 198.0 uS/cm Lab
Chloride 22.8 mg/L Lab
Turbidity 463.0 NTU Lab
Solids, Total Suspended 487.0 mg/L Lab
Soluble Reactive Phosphorus (as P) 163.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 926.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.13 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 2.73 mg/L Lab
E. Coli 12000.0 Colonies/100 ml Lab
Pleasant Brook/Stewart Temperature 15.0 C Field
Specific Conductance 707.0 uS/cm Lab
Chloride 23.6 mg/L Lab
Turbidity 632.0 NTU Lab
Solids, Total Suspended 690.0 mg/L Lab
Soluble Reactive Phosphorus (as P) 160.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 1221.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.278 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 4.08 mg/L Lab
E. Coli 17600.0 Colonies/100 ml Lab
Unnamed/Cayuga Heights Temperature 15.0 C Field
Specific Conductance 209.0 uS/cm Lab
Chloride 28.7 mg/L Lab
Turbidity 304.0 NTU Lab
Solids, Total Suspended 364.0 mg/L Lab
Soluble Reactive Phosphorus (as P) 112.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 708.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.17 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 2.15 mg/L Lab
E. Coli 10600.0 Colonies/100 ml Lab