Cayuga Nature Center Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Cayuga Nature Center Creek at Comstock E. Coli 1000.0 Colonies/100 ml Lab
Temperature 7.0 C Field
Specific Conductance 613.0 uS/cm Lab
Chloride 60.7 mg/L Lab
Turbidity 1.5 NTU Lab
Solids, Total Suspended 0.25 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 9.89 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 18.5 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.47 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.17 mg/L non-detect Lab
Cayuga Nature Center Creek at Center - Upstream Temperature 7.0 C Field
Specific Conductance 611.0 uS/cm Lab
Chloride 63.9 mg/L Lab
Turbidity 1.4 NTU Lab
Solids, Total Suspended 0.25 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 8.66 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 17.7 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.44 mg/L Lab
E. Coli 1400.0 Colonies/100 ml Lab