Reeder Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Reeder Creek @ Access Road Solids, Total Suspended 0.63 mg/L non-detect Lab
Temperature 2.5 C Field
Specific Conductance 585.0 uS/cm Lab
Total Phosphorus (as P) 158.3 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.5 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.12 mg/L non-detect Lab
E. Coli 33.0 Colonies/100 ml Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 161.4 ug/L Lab
Reeder Creek @ N. Patrol Rd Soluble Reactive Phosphorus, Field-Filtered (as P) 174.3 ug/L Lab
Temperature 2.0 C Field
Specific Conductance 590.0 uS/cm Lab
Solids, Total Suspended 2.75 mg/L Lab
Total Phosphorus (as P) 193.6 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.56 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.12 mg/L non-detect Lab
E. Coli 33.0 Colonies/100 ml Lab
Reeder Creek Mouth Temperature 2.5 C Field
Specific Conductance 606.0 uS/cm Lab
Solids, Total Suspended 0.63 mg/L non-detect Lab
Total Phosphorus (as P) 117.1 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.886 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.28 mg/L Estimate Lab
E. Coli 167.0 Colonies/100 ml Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 93.6 ug/L Lab