Notes: Time is average of the sampling times of the locations.
Burroughs Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Units Remarks Location
Burroughs Creek @ Seybolt Road
(CABUS)
Turbidity 23.0 NTU Lab
Total Phosphorus (as P) 319.0 ug/L Lab
Total Nitrogen 3.98 mg/L Not certifiable Lab
Temperature 18.5 C Field
Specific Conductance 609.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 254.0 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 4.5 mg/L Lab
Hydrogen Ion (pH) 7.5 Unitless (negative logarithm of H ion concentration) Not certifiable Lab
Hardness, Total 258.0 mg CaCO3/L Lab
E. Coli 4280.0 Colonies/100 ml Lab
Chloride 23.1 mg/L Lab
Alkalinity 119.0 mg CaCO3/L Sample collected with head space Lab
Williamson Creek
(CAWM)
Turbidity 110.0 NTU Lab
Total Phosphorus (as P) 259.0 ug/L Lab
Total Nitrogen 13.2 mg/L Not certifiable Lab
Temperature 19.0 C Field
Specific Conductance 536.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 157.0 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 16.8 mg/L Lab
E. Coli 2980.0 Colonies/100 ml Lab
Chloride 14.5 mg/L Lab
Burroughs Creek
(CABU)
Turbidity 38.0 NTU Lab
Total Phosphorus (as P) 263.0 ug/L Lab
Total Nitrogen 16.6 mg/L Not certifiable Lab
Temperature 18.5 C Field
Specific Conductance 627.0 uS/cm Lab
Soluble Reactive Phosphorus (as P) 191.0 ug/L Exceeded 15 min. holding time for filtration Lab
Solids, Total Suspended 17.5 mg/L Lab
E. Coli 4400.0 Colonies/100 ml Lab
Chloride 21.8 mg/L Lab