Synoptic Monitoring Event on September 18, 2018
for Virgil Creek under Stormwater conditions
Notes: Event Time = Time of sampling (Eastern Time) at stream mouth (Virgil Creek Freeville)
Virgil Creek Monitoring Event Graph
This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.
Event Results
Scroll down to view the event results for each monitoring location.
Location | Analyte | Value | Units | Remarks | Location |
---|---|---|---|---|---|
Dryden Lake Park (DLP) |
Turbidity | 42.0 | NTU | Lab | |
Total Phosphorus (as P) | 93.9 | ug/L | Lab | ||
Total Nitrogen | 1.1 | mg/L | Not certifiable | Lab | |
Temperature | 17.0 | C | Field | ||
Specific Conductance | 200.0 | uS/cm | Lab | ||
Soluble Reactive Phosphorus (as P) | 11.5 | ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Solids, Total Suspended | 29.7 | mg/L | Lab | ||
E. Coli | 500.0 | Colonies/100 ml | Lab | ||
Chloride | 11.3 | mg/L | Lab | ||
Dryden Lake Inlet (DLI) |
Turbidity | 35.0 | NTU | Lab | |
Total Phosphorus (as P) | 99.9 | ug/L | Lab | ||
Total Nitrogen | 1.06 | mg/L | Not certifiable | Lab | |
Temperature | 13.0 | C | Field | ||
Specific Conductance | 81.0 | uS/cm | Lab | ||
Soluble Reactive Phosphorus (as P) | 39.0 | ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Solids, Total Suspended | 36.7 | mg/L | Lab | ||
E. Coli | 3400.0 | Colonies/100 ml | Lab | ||
Chloride | 3.2 | mg/L | Lab | ||
Virgil Creek Freeville (VCF) |
Turbidity | 322.0 | NTU | Lab | |
Total Phosphorus (as P) | 417.0 | ug/L | Lab | ||
Total Nitrogen | 1.6 | mg/L | Not certifiable | Lab | |
Specific Conductance | 256.0 | uS/cm | Lab | ||
Soluble Reactive Phosphorus (as P) | 27.5 | ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Solids, Total Suspended | 372.0 | mg/L | Lab | ||
E. Coli | 11400.0 | Colonies/100 ml | Lab | ||
Chloride | 19.8 | mg/L | Lab | ||
Spring House Bridge (VCSB) |
Turbidity | 240.0 | NTU | Lab | |
Total Phosphorus (as P) | 882.0 | ug/L | Lab | ||
Total Nitrogen | 1.56 | mg/L | Not certifiable | Lab | |
Temperature | 13.0 | C | Field | ||
Specific Conductance | 225.0 | uS/cm | Lab | ||
Soluble Reactive Phosphorus (as P) | 21.2 | ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Solids, Total Suspended | 270.0 | mg/L | Lab | ||
E. Coli | 11400.0 | Colonies/100 ml | Lab | ||
Chloride | 14.9 | mg/L | Lab | ||
Dryden Lake Outlet (VCDL) |
Turbidity | 75.0 | NTU | Lab | |
Total Phosphorus (as P) | 176.0 | ug/L | Lab | ||
Total Nitrogen | 1.46 | mg/L | Not certifiable | Lab | |
Temperature | 13.0 | C | Field | ||
Specific Conductance | 204.0 | uS/cm | Lab | ||
Soluble Reactive Phosphorus (as P) | 4.4 | ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Solids, Total Suspended | 84.0 | mg/L | Lab | ||
E. Coli | 1500.0 | Colonies/100 ml | Lab | ||
Chloride | 11.5 | mg/L | Lab | ||
Virgil Creek Road (VC3) |
Turbidity | 141.0 | NTU | Lab | |
Total Phosphorus (as P) | 405.0 | ug/L | Lab | ||
Total Nitrogen | 1.42 | mg/L | Not certifiable | Lab | |
Temperature | 15.0 | C | Field | ||
Specific Conductance | 175.0 | uS/cm | Lab | ||
Soluble Reactive Phosphorus (as P) | 32.7 | ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Solids, Total Suspended | 163.0 | mg/L | Lab | ||
E. Coli | 11300.0 | Colonies/100 ml | Lab | ||
Chloride | 13.4 | mg/L | Lab |