Reeder Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Reeder Creek @ Access Road Temperature 5.5 C Field
Specific Conductance 862.0 uS/cm Lab
Solids, Total Suspended 0.63 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 686.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 1310.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.092 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.47 mg/L Lab
E. Coli 50.0 Colonies/100 ml non-detect Lab
Reeder Creek @ N. Patrol Rd Temperature 5.0 C Field
Specific Conductance 943.0 uS/cm Lab
Solids, Total Suspended 0.63 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 806.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 878.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.35 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.56 mg/L Lab
E. Coli 50.0 Colonies/100 ml non-detect Lab
Reeder Creek Mouth Temperature 6.0 C Field
Specific Conductance 837.0 uS/cm Lab
Solids, Total Suspended 0.63 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 522.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 834.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.919 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 1.72 mg/L Lab
E. Coli 100.0 Colonies/100 ml Lab
Soluble Reactive Phosphorus, Field-Filtered (as P) 531.0 ug/L Lab