Trumansburg Creek Synoptic Monitoring Event on June 27, 2018, under Base Flow conditions
Trumansburg Creek Monitoring Event Graph
This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.
Event Results
Scroll down to view the event results for each monitoring location.
Location | Analyte | Value | Remarks | Location |
---|---|---|---|---|
Curry Road | Temperature | 15.0 C | Field | |
E. Coli | 1560.0 Colonies/100 ml | Lab | ||
Total Nitrogen | 0.35 mg/L | Not certifiable | Lab | |
Specific Conductance | 464.0 uS/cm | Lab | ||
Chloride | 24.4 mg/L | Lab | ||
Turbidity | 10.7 NTU | Lab | ||
Solids, Total Suspended | 9.25 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 25.7 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 39.2 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.35 mg/L | Lab | ||
Lake Street Bridge | Chloride | 64.6 mg/L | Lab | |
Turbidity | 30.0 NTU | Lab | ||
Solids, Total Suspended | 44.0 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 39.1 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 80.4 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.79 mg/L | Lab | ||
E. Coli | 1440.0 Colonies/100 ml | Lab | ||
Total Nitrogen | 1.3 mg/L | Not certifiable | Lab | |
Specific Conductance | 579.0 uS/cm | Lab | ||
Camp Barton | Temperature | 15.0 C | Field | |
Specific Conductance | 693.0 uS/cm | Lab | ||
Chloride | 90.0 mg/L | Lab | ||
Turbidity | 9.5 NTU | Lab | ||
Solids, Total Suspended | 27.5 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 59.8 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 76.1 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 2.9 mg/L | Lab | ||
E. Coli | 180.0 Colonies/100 ml | Lab | ||
Total Nitrogen | 3.0 mg/L | Not certifiable | Lab | |
Salo Drive | Soluble Reactive Phosphorus (as P) | 22.8 ug/L | Exceeded 15 min. holding time for filtration | Lab |
Total Phosphorus (as P) | 29.4 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 1.42 mg/L | Lab | ||
E. Coli | 1610.0 Colonies/100 ml | Lab | ||
Total Nitrogen | 1.4 mg/L | Not certifiable | Lab | |
Temperature | 17.0 C | Field | ||
Specific Conductance | 539.0 uS/cm | Lab | ||
Chloride | 27.0 mg/L | Lab | ||
Turbidity | 6.5 NTU | Lab | ||
Solids, Total Suspended | 9.0 mg/L | Lab | ||
Boardman Creek | Temperature | 15.0 C | Field | |
Specific Conductance | 452.0 uS/cm | Lab | ||
Chloride | 25.7 mg/L | Lab | ||
Turbidity | 3.3 NTU | Lab | ||
Solids, Total Suspended | 1.75 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 34.1 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 35.0 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.63 mg/L | Lab | ||
E. Coli | 320.0 Colonies/100 ml | Lab | ||
Total Nitrogen | 0.82 mg/L | Not certifiable | Lab | |
Outfall of Sewage Plant | Temperature | 15.0 C | Field | |
Specific Conductance | 1186.0 uS/cm | Lab | ||
Chloride | 167.0 mg/L | Lab | ||
Turbidity | 1.3 NTU | Lab | ||
Solids, Total Suspended | 1.25 mg/L | Lab | ||
Soluble Reactive Phosphorus (as P) | 739.0 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 730.0 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 26.9 mg/L | Lab | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Nitrogen | 27.8 mg/L | Not certifiable | Lab |