Kashong Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Bridge at Thistle Street Temperature 1.5 C Field
Specific Conductance 821.0 uS/cm Lab
Solids, Total Suspended 0.63 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 17.3 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 11.8 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.53 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.45 mg/L Lab
E. Coli 20.0 Colonies/100 ml Lab
Total Coliform 480.0 Colonies/100 ml Lab
Bridge at Bellona Temperature 1.0 C Field
Specific Conductance 818.0 uS/cm Lab
Solids, Total Suspended 0.63 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 11.6 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 11.5 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.97 mg/L Lab
E. Coli 20.0 Colonies/100 ml Lab
Total Coliform 600.0 Colonies/100 ml Lab
Bridge at Route 14 Temperature 3.0 C Field
Specific Conductance 818.0 uS/cm Lab
Solids, Total Suspended 0.63 mg/L non-detect Lab
Soluble Reactive Phosphorus (as P) 15.9 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 11.1 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 1.89 mg/L Lab
Kjeldahl Nitrogen, Total (as N) 0.37 mg/L Lab
E. Coli 40.0 Colonies/100 ml Lab
Total Coliform 1180.0 Colonies/100 ml Lab