Reeder Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Reeder Creek @ Access Road Temperature 10.0 C Field
Specific Conductance 558.0 uS/cm Lab
Solids, Total Suspended 2.5 mg/L Lab
Soluble Reactive Phosphorus (as P) 303.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 280.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.59 mg/L
Kjeldahl Nitrogen, Total (as N) 0.49 mg/L Lab
E. Coli 700.0 Colonies/100 ml Lab
Total Coliform 19000.0 Colonies/100 ml Lab
Reeder Creek @ N. Patrol Rd Temperature 10.0 C Field
Specific Conductance 513.0 uS/cm Lab
Solids, Total Suspended 1.75 mg/L Lab
Soluble Reactive Phosphorus (as P) 251.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 231.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.32 mg/L
Kjeldahl Nitrogen, Total (as N) 0.37 mg/L Lab
E. Coli 620.0 Colonies/100 ml Lab
Total Coliform 21000.0 Colonies/100 ml Lab
Reeder Creek Mouth Temperature 9.5 C Field
Specific Conductance 547.0 uS/cm Lab
Solids, Total Suspended 6.5 mg/L Lab
Soluble Reactive Phosphorus (as P) 213.0 ug/L Exceeded 15 min. holding time for filtration Lab
Total Phosphorus (as P) 214.0 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 2.92 mg/L
Kjeldahl Nitrogen, Total (as N) 0.66 mg/L Lab
E. Coli 660.0 Colonies/100 ml Lab
Total Coliform 22500.0 Colonies/100 ml Lab