Pony Hollow Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Pony Hollow Creek @ Cayuta Rd. Temperature 10.0 C Field
Kjeldahl Nitrogen, Total (as N) 0.13 mg/L non-detect Lab
E. Coli 120.0 Colonies/100 ml Lab
Total Coliform 1060.0 Colonies/100 ml Lab
Hydrogen Ion (pH) 7.75 Unitless (negative logarithm of H ion concentration) Not certifiable Lab
Specific Conductance 329.0 uS/cm Lab
Alkalinity 135.0 mg CaCO3/L Sample collected with head space Lab
Hardness, Total 157.0 mg CaCO3/L Lab
Chloride 15.1 mg/L Lab
Turbidity 1.4 NTU Lab
Solids, Total Suspended 1.25 mg/L Lab
Total Phosphorus (as P) 8.3 ug/L Lab
Nitrate-+Nitrite-Nitrogen (as N) 0.9 mg/L Lab
Pony Hollow Creek @ Connecticut Hill Rd. Soluble Reactive Phosphorus (as P) 14.1 ug/L Exceeded 15 min. holding time for filtration Lab