Cayuga Lake Synoptic Monitoring Event on July 19, 2016, under Base Flow conditions
Cayuga Lake Monitoring Event Graph
This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.
Event Results
Scroll down to view the event results for each monitoring location.
Location | Analyte | Value | Remarks | Location |
---|---|---|---|---|
Cayuga Lake near Mouth of Salmon Creek | Temperature | 22.0 C | Field | |
Hydrogen Ion (pH) | 8.75 Unitless (negative logarithm of H ion concentration) | Not certifiable | Lab | |
Turbidity | 3.2 NTU | Lab | ||
Soluble Reactive Phosphorus (as P) | 2.9 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 15.2 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.68 mg/L | Lab | ||
Chlorophyll | 11.1 ug/L | Lab | ||
Secchi Depth | 2.5 m | Field | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 1100.0 Colonies/100 ml | Lab | ||
Cayuga Lake near Paines Creek Mouth | Temperature | 21.0 C | Field | |
Hydrogen Ion (pH) | 8.5 Unitless (negative logarithm of H ion concentration) | Not certifiable | Lab | |
Turbidity | 2.0 NTU | Lab | ||
Total Phosphorus (as P) | 14.0 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.67 mg/L | Lab | ||
Chlorophyll | 6.25 ug/L | Lab | ||
Secchi Depth | 3.0 m | Field | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 320.0 Colonies/100 ml | Lab | ||
Cayuga Lake near Mill Creek Mouth | Temperature | 21.0 C | Field | |
Hydrogen Ion (pH) | 8.5 Unitless (negative logarithm of H ion concentration) | Not certifiable | Lab | |
Turbidity | 3.8 NTU | Lab | ||
Soluble Reactive Phosphorus (as P) | 4.6 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 14.9 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.68 mg/L | Lab | ||
Chlorophyll | 9.02 ug/L | Lab | ||
Secchi Depth | 3.0 m | Field | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 1640.0 Colonies/100 ml | Lab | ||
Cayuga Lake near Town Line Creek Mouth | Temperature | 21.0 C | Field | |
Hydrogen Ion (pH) | 8.5 Unitless (negative logarithm of H ion concentration) | Not certifiable | Lab | |
Turbidity | 2.8 NTU | Lab | ||
Soluble Reactive Phosphorus (as P) | 5.4 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 16.3 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.68 mg/L | Lab | ||
Chlorophyll | 6.53 ug/L | Lab | ||
Secchi Depth | 3.5 m | Field | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 1500.0 Colonies/100 ml | Lab | ||
Cayuga Lake near Dean\s Creek Mouth | Temperature | 22.0 C | Field | |
Hydrogen Ion (pH) | 8.5 Unitless (negative logarithm of H ion concentration) | Not certifiable | Lab | |
Turbidity | 2.4 NTU | Lab | ||
Soluble Reactive Phosphorus (as P) | 6.2 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 15.2 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.68 mg/L | Lab | ||
Chlorophyll | 5.28 ug/L | Lab | ||
Secchi Depth | 3.5 m | Field | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 1340.0 Colonies/100 ml | Lab | ||
Cayuga Lake Control | Temperature | 20.0 C | Field | |
Hydrogen Ion (pH) | 8.75 Unitless (negative logarithm of H ion concentration) | Not certifiable | Lab | |
Turbidity | 2.1 NTU | Lab | ||
Soluble Reactive Phosphorus (as P) | 3.8 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 17.6 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.68 mg/L | Lab | ||
Chlorophyll | 27.5 ug/L | Lab | ||
Secchi Depth | 3.0 m | Field | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 720.0 Colonies/100 ml | Lab | ||
Cayuga Lake near Trumansburg Creek Mouth | Temperature | 21.0 C | Field | |
Hydrogen Ion (pH) | 8.75 Unitless (negative logarithm of H ion concentration) | Not certifiable | Lab | |
Turbidity | 1.7 NTU | Lab | ||
Soluble Reactive Phosphorus (as P) | 3.3 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 12.9 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.7 mg/L | Lab | ||
Chlorophyll | 7.7 ug/L | Lab | ||
Secchi Depth | 3.0 m | Field | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 580.0 Colonies/100 ml | Lab | ||
Cayuga Lake near Taughannock Creek Mouth | Temperature | 22.0 C | Field | |
Hydrogen Ion (pH) | 8.75 Unitless (negative logarithm of H ion concentration) | Not certifiable | Lab | |
Turbidity | 1.7 NTU | Lab | ||
Soluble Reactive Phosphorus (as P) | 3.5 ug/L | Exceeded 15 min. holding time for filtration | Lab | |
Total Phosphorus (as P) | 12.6 ug/L | Lab | ||
Nitrate-+Nitrite-Nitrogen (as N) | 0.73 mg/L | Lab | ||
Chlorophyll | 7.13 ug/L | Lab | ||
Secchi Depth | 3.0 m | Field | ||
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 6500.0 Colonies/100 ml | Lab |