Fly Meadow Creek Monitoring Event Graph

This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.

Event Results

Scroll down to view the event results for each monitoring location.

Location Analyte Value Remarks Location
Fly meadow Tributary @ Old Mill Dam Temperature 20.0 C Field
Hydrogen Ion (pH) 8.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 108.0 uS/cm Field
Hardness, Total 48.0 mg CaCO3/L Field
Dissolved Oxygen 7.2 mg/L Field
Preston Public Spring Temperature 12.1 C Field
Hydrogen Ion (pH) 6.25 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 93.0 uS/cm Field
Hardness, Total 44.0 mg CaCO3/L Field
Dissolved Oxygen 4.6 mg/L Field
Fly Meadow Creek @ Georgetown PullOver Dissolved Oxygen 7.4 mg/L Field
Temperature 20.3 C Field
Hydrogen Ion (pH) 8.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 107.0 uS/cm Field
Hardness, Total 41.0 mg CaCO3/L Field
Fly Meadow Creek @ Tamarac Road Bridge Hardness, Total 40.0 mg CaCO3/L Field
Dissolved Oxygen 7.7 mg/L Field
Temperature 19.5 C Field
Hydrogen Ion (pH) 8.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 99.0 uS/cm Field
Fly Meadow Creek @ Ruth\s Bridge Temperature 19.1 C Field
Hydrogen Ion (pH) 8.0 Unitless (negative logarithm of H ion concentration) Field
Specific Conductance 90.0 uS/cm Field
Hardness, Total 38.0 mg CaCO3/L Field
Dissolved Oxygen 7.4 mg/L Field