Trumansburg Creek Partial Monitoring Event on July 29, 2014, under Base Flow conditions
Trumansburg Creek Monitoring Event Graph
This bar graph reports the raw data for each location that was sampled as part of the monitoring event conducted on this date. To view results for individual water quality indicators, click-off other indicators in the legend at the bottom of the graph.
Event Results
Scroll down to view the event results for each monitoring location.
Location | Analyte | Value | Remarks | Location |
---|---|---|---|---|
Lake Street Bridge | Temperature | 15.0 C | Field | |
E. Coli | 1420.0 Colonies/100 ml | Lab | ||
Fecal Coliform | 1280.0 Colonies/100 ml | Lab | ||
Total Coliform | 35500.0 Colonies/100 ml | Lab | ||
Camp Barton | E. Coli | 1540.0 Colonies/100 ml | Lab | |
Fecal Coliform | 1040.0 Colonies/100 ml | Lab | ||
Total Coliform | 49000.0 Colonies/100 ml | Lab | ||
Outfall of Sewage Plant | Temperature | 18.0 C | Field | |
E. Coli | 10.0 Colonies/100 ml | non-detect | Lab | |
Fecal Coliform | 10.0 Colonies/100 ml | non-detect | Lab | |
Total Coliform | 40.0 Colonies/100 ml | Lab | ||
Camp Barton Falls | Temperature | 15.0 C | Field |